N2 · Cognitive and neurological health · 2026-11-16
Dementia Risk Stratification from Brain MRI and Speech
Study whether imaging and speech features retain their predictive value across hospitals and equipment.
References and implementation
- PROBAST+AI: an updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods
- TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods
- Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI
- Datasheets for datasets
- Alzheimer’s Dementia Recognition Through Spontaneous Speech: The ADReSS Challenge
- Model Cards for Model Reporting
- OASIS-3: Longitudinal Neuroimaging, Clinical, and Cognitive Dataset for Normal Aging and Alzheimer Disease
- The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments
- Open Access Series of Imaging Studies: Longitudinal MRI Data in Nondemented and Demented Older Adults
- Open Access Series of Imaging Studies (OASIS): Cross-sectional MRI Data in Young, Middle Aged, Nondemented, and Demented Older Adults
Research question and target
Evaluate MRI and PET features along with pauses, vocabulary and sentence features from speech. Compare fixed models on independent cohorts.
- Internal target
- External cohort AUROC of at least 0.90
- Programme
- Cognitive and neurological health
- Evidence on this record
- System structure
- Clinical Decision Support Software Architecture
Evaluation data
- OASIS-2 MRI visit metadata
Official OASIS-2 demographic workbook and MRI archives
Manifest locked - DementiaBank ADReSS Challenge 2020
2020 official split and test labels
Split rule locked - ADNI / OASIS-3 / DementiaBank
Provider data definitions and access conditions
Blocked
Synthetic harness · cog16
Multi-site MRI and speech fusion: cross-cohort validation on synthetic cohorts
On synthetic multi-site cohorts, the external AUROC for separating controls from MCI or dementia was 0.932 (DeLong 95% lower bound 0.909) on 540 held-out cases in one direction and 0.926 (0.905) on 560 in the other, with harmonisation referenced to control cases. The internal target is 0.90.
- Seed replications at or above the target
- 9 of 10; lower bound above target in 7; minimum 0.881
- Synthetic paired fusion
- AUROC 0.955
- Conditions below the target
- ZERO_ADAPTATION_B_TO_A, SPEECH_UNSEEN_UNIT, EFFECT_SCALE_0.5, EFFECT_SCALE_0.75
- AUROC figures recomputed by the auditor
- 21
Limits
- All cohorts are synthetic and the AUROC follows the assumed disease effect size: at 0.5, 0.75 times the assumed effect it falls below the target. No ADNI, OASIS-3 or DementiaBank data were read.
- The public datasets do not link MRI and speech from the same participant. Paired fusion was evaluated only on a synthetic paired cohort and is reported separately from the primary result.
- Harmonising a scanner that was absent from training needs labelled control cases from that site, kept apart from the test split. Without them the design holds the score instead of reporting it.
- FreeSurfer and acoustic feature extraction, the PyTorch modules and domain-adversarial training are specified but were not run. The harness trains a standard-library reference network on already extracted synthetic features.
- The auditor recomputes each AUROC and interval from stored per-case scores. It does not refit the models that produced the scores.
- The output is a research risk score for clinician review. It does not issue a diagnosis.
Synthetic inputs only (synthetic_only). These are virtual metrics on synthetic cohorts. No ADNI, OASIS-3 or DementiaBank data were read, no real cohort has been evaluated, clinical validity has not been assessed and no auditor has signed the result. A separate audit program passed 4 of 4 gates.
Audit record (JSON) · Run output (JSON) · N2 design specification: multi-site MRI and speech fusion (KR) · N1 and N2 replay record (KR) · N1 and N2 cross-model review log (KR) (KR)
python3 -B -m cog16.orchestrate --check evidence/cog16-run.json
python3 -B -m cog16.audit --run evidence/cog16-run.json --output evidence/cog16-audit.json
python3 -B -m unittest discover -s tests -p 'test_cog16_*.py' -vSources and eligibility
The longitudinal imaging, clinical and cognition cohort requires a NITRC account. Linkage to DementiaBank participants remains unverified.
Includes imaging, diagnosis and cognitive assessments. Confirm coverage by study phase and visit-level variables.
Audio, transcripts and diagnostic coverage vary by corpus. Matching the same people to scans remains unverified.
Boundary cases
- Whether MRI and speech can be matched by participant and visit
- Performance changes across scanners, sites and audio settings
- Lock model weights and diagnostic definitions before external evaluation
Common synthetic checks
- Disjoint sites, scanners and participants, with subject-level modality pairing · 5/5 matched
Interpretation and next evaluation
Single-modality evaluation is available pending imaging and speech matched to the same participant and diagnostic visit.
- Next check
- After approved data import, run the same harness with ADNI and OASIS-3 as the two external directions and evaluate speech separately; the synthetic figures are then replaced.