S2 · Patient safety · 2026-11-16
Early Warning for Patients at High Risk of Falls
Replay acceleration and gait records to measure warning lead time and distinguish falls from everyday movement.
References and implementation
- PROBAST+AI: an updated quality, risk of bias, and applicability assessment tool for prediction models using regression or artificial intelligence methods
- MIMIC-IV
- TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods
- Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI
- A Large-Scale Open Motion Dataset (KFall) and Benchmark Algorithms for Detecting Pre-impact Fall of the Elderly Using Wearable Inertial Sensors
- Datasheets for datasets
- Ethics and governance of artificial intelligence for health
- Calibration: the Achilles heel of predictive analytics
- Model Cards for Model Reporting
- UP-Fall Detection Dataset: A Multimodal Approach
- SisFall: A Fall and Movement Dataset
- UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
- The FARSEEING real-world fall repository: a large-scale collaborative database to collect and share sensor signals from real-world falls
- The Precision-Recall Plot Is More Informative than the ROC Plot When Evaluating Binary Classifiers on Imbalanced Datasets
- Decision curve analysis: a novel method for evaluating prediction models
- Time-Dependent ROC Curves for Censored Survival Data and a Diagnostic Marker
Research question and target
Evaluate a warning policy on timestamped sensor streams. Separate detection of falls from prediction before impact.
- Internal target
- At least 92% early-warning sensitivity in the high-risk group
- Programme
- Patient safety
- Evidence on this record
Evaluation data
- UP-Fall Detection Dataset 2019
Sensors 19(9):1988 · 17 publisher-listed groups
Manifest locked - KFall 2021
DOI 10.3389/fnagi.2021.692865
Manifest locked - FARSEEING observed falls and eICU-CRD 2.0
2016 FARSEEING study · eICU 2.0
Blocked
Sources and eligibility
Contains enacted falls and everyday activities. Performance for spontaneous falls in hospitals requires hospital data.
Healthy volunteers performed falls and everyday activities. Verify impact time and observation coverage before each event.
Multicentre critical care records. A reference linking individual gait sensors to real fall time and impact remains unverified.
Boundary cases
- Event-level assessment of a warning at least three seconds before impact
- False alarms per hour from movements such as picking up objects or turning in bed
- Abstention with sensor displacement, device removal or missing samples
Common synthetic checks
- Information cutoff and warning lead time · 6/6 matched
Interpretation and next evaluation
A laboratory fall label and an advance alert for a patient are different endpoints. Measure lead time only for records that cover at least three seconds before impact.
- Next check
- Register participant and event splits, alert lead time and the time denominator for false alarms.